CE marking - EMC and radio frequency tests

Measurement at 3m in Fully Anechoic Room (FAR)

Cage FAR (Fully Anechoic Room)

A Faraday room with ferrite tiles and pyramidal absorbers builded to be a full anechoic room can comply the site attenuation of an open area test site.
The emission measurements are equivalent and have the advantage to be also insulated from exterior sources of electromagnetic noise.
We obtain faster measurments in FAR

A FAR can be used for EMC tests (emission, immunity) and radio frequency tests.

  • Radiated emission type CISPR 16-1-4, ANSI C63.4 from 30MHz to 26GHz 
  • Radiated immunity tests type IEC 61000-4-3, EN 61000-4-3 from 80 MHz to 6 GHz 
  • Radio emission type EN 300 330 / EN300220 / EN300440

 

 

 

Measurement at 3 or 10m in our large semi-anechoic chamber

With its dimension (15m x 10m x 7m),  our Faraday room dedicated to the measurements at 3 or 10m worth its name of "large room".
With its large shielded door, these room can be used to test huge equipments.

These room can be used for EMC tests (emission, immunity) and radio frequency tests.

  • Radiated emission type CISPR 16-1-4, ANSI C63.4 from 30MHz to 26GHz (possibilty to extend to 40 GHz)
  • Radiated immunity tests type IEC 61000-4-3, EN 61000-4-3 from 80 MHz to 6 GHz (possibilty to extend to 40 GHz)
  • Radio emission type EN 300 330 / EN300220 / EN300440

 

 

 

Measurement at 3 or 10m in our open area test site 

Site de mesure en espace libreReference measurments for the emission tests, the equipment under tests is installed on a turntable  (0 to 360 degrees), the height of the antenna is adjusted between 1 to  4m. For each frequency detected, the position of the turntable and the height of the antenna are optimized to obtain the high value of the RF field.
The ambiant radio frequency spectrum add an electromagnetic noise and complexify the measure and its duration. 

Our open area test site is near our lab.

It is used for EMC emission tests and radio frequency tests.

  • Radiated emission type CISPR 16-1-4 from 30MHz to 1GHz 
  • Radio emission type EN 300 330 / EN300220 / EN300440

 

 

 

Electrical tests, conducted emission and immunity, ...

Flickers et harmonics EN 61100 3-2 & 3-3 and EN 61100 3-11 & 3-12

  • Single and three phase 16 A
  • Single and three phase 32A

 

Conducted emission type CISPR 16-1-4/CISPR 11/CISPR 22/CISPR 14 from 9kHz to 30MHz:

  • LISN 1 phase - 10A 
  • LISN 3 phases - 100A
  • LISN 3 phases - 400A
  • 1 to 6m  cable slide bar for disturbing power emission

 

Conducted immunity:

  • EN 61100 4-6 - 10Veff from150kHz to 230MHz.

 

Magnetic immunity:

  • EN 61100 4-8 Magnetic field by immersion 30A/m 50/60Hz.

 

Electrical tests:

  • EN 61100 4-2 Electrostatic discharge up to 30kV.
  • EN 61100 4-4 CDN 3 phases 30A, amplitude burst 4.4kV.
  • EN 61100 4-4 CDN 3 phases 100A, amplitude burst 4.4kV.
  • EN 61100 4-5 CDN 3 phases 25A amplitude 6.6 KV.
  • EN 61100 4-5 CDN 3 phases 150A amplitude 6.6 KV.
  • EN 61100 4-11 1 phase, 3 phases and DC.

 

 

 

A recognized expertise in addition to our facilities 

Expertise CEM et radioA know-how in technical assistance and advices to solve design issue.
Recommandations according the state of the art to take into account the EMC phenomena, including EMF.
Intervention in France and in the world on disturbed sites (EMC). 

 

 

 

 

 

Standards - CE marking and international regulations

EMC directive 2004/108/EC

EN 55016-2-1 / EN 55016-2-2 / EN 55016-2-3
EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12
EN 61000-4-(2 à 6, 8 à 13, 16 et 17)
EN 61000-6-(1 à 4)
FCC PART 15 / ICES-003 / NMB-003 / ANSI C63.4

 

Medical devices directive 93/42/EEC

CEI / EN 60601-1-2

 

R&TTE 99/5/EC directive

EN 301 489-X and associated standards ETS
EN 300 330 / EN300220-1 et-2 / EN302291-1et-2 / EN301511 / EN300328 / EN 301908-1

 

Board of test method 

Type Object Ref

Emission
Immunity

Railway applications – EMC – part 3-2 : Rolling equipment – Apparatus

EN 50121-3-2

Emission
Immunity

Railway applications – EMC– part 4 : signaling and telecommunication apparatus

EN 50121-4

Emission
Immunity

Fire detection, intruder and social alarm equipments

EN 50130-4

Emission
Immunity

Railway applications – Electronic equipments used on rolling equipment

EN 50155

Emission
Immunity

Road Traffic Signal Systems

EN 50293

Emission
Immunity

Measurement relay and protection devices

EN 50263

Emission
Immunity

General prescription, tests and tests conditions - Metering equipment (precision class A, B et C) 

EN 50470-1

Emission

Industrial, scientific and medical apparatus

CISPR 11
EN 55011
Emission Electrical, electronical, electrical domestic and handheld tools equipments Devices with motors CISPR 14-1
EN 55014-1
Immunity Electrical, electronical, electrical domestic and handheld tools equipments Devices with motors CISPR 14-2
EN 55014-2
Emission Electrical and electronival device, information processing equipment CISPR 22
EN 55022
Immunity Information processing equipment CISPR 24
EN 55024
Emission Electromagnetic compatibility of multimedia equipment - Emission requirements CISPR 32
EN 55032
Immunity Measuring relays and protection equipment CEI 60255-11
EN 60255-11
Emission Measuring relays and protection equipment CEI 60255-25
EN 60255-25
Emission
Immunity
Measuring relays and protection equipment CEI 60255-26
EN 60255-26
Emission
Immunity
Medical electrical equipment CEI 60601-1-2
EN 60601-1-2
Emission
Immunity
Medical electrical equipment - Part 2-4 : particular requirements for basic safety and essential performance of cardiac defibrillators CEI 60601-2-4
EN 60601-2-4
Emission
Immunity
Maritime navigation and radiocommunication equipment and systems EN 60945
Emission
Immunity
Low-voltage switchgear and controlgear - Part 5-1 : control circuit devices and switching elements - Electromechanical control circuit devices CEI 60947-5-1
EN 60947-5-1
Emission
Immunity
Low-voltage switchgear and controlgear - Part 5-2 : control circuit devices and switching elements - Proximity switches CEI 60947-5-2
EN 60947-5-2
Immunity Electromagnetic compatibility (EMC) - Part 6-1 : generic standards - Immunity for residential, commercial and light-industrial environments CEI 61000-6-1
EN 61000-6-1
Immunity Electromagnetic compatibility (EMC) - Part 6-2 : generic standards - Immunity for industrial environments CEI 61000-6-2
EN 61000-6-2
Emission Electromagnetic compatibility (EMC) - Part 6-3 : generic standards - Emission standard for residential, commercial and light-industrial environments CEI 61000-6-3
EN 61000-6-3
Emission Electromagnetic compatibility (EMC) - Part 6-4 : generic standards - Emission standard for industrial environments CEI 61000-6-4
EN 61000-6-4
Emission
Immunity
Programmable controllers - Part 2 : equipment requirements and tests CEI 61131-2
EN 61131-2
Emission
Immunity
Live working - Voltage detectors - Part 3 : two-pole low-voltage type CEI 61243-3
Emission
Immunity
Electrical equipment for measurement, control and laboratory use CEI 61326-1
EN 61326-1
Immunity Equipment for general lighting purposes  CEI 61547
EN 61547
Immunity Installed monitors for the control and detection of gamma radiations contained in recyclable or non recyclable materials transported by vehicles CEI 62022
EN 62022
Emission
Immunity
Radio receivers and transmitters EN 301 489-01
EN 301 489 – 1 à 34
Emission
Immunity
Adjustable speed electrical power drive systems CEI 61800-3
EN 61800-3
Emission
Immunity
Remote Control Interface Box switches 400A (ITI) HN 64-S-44
Immunity Measuring systems for gaseous fuel OIML R140
Emission
Immunity
Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargers ISO 7176-21
Emission
Immunity
wheeled agricultural or forestry tractors Directive 73/322/CE
Directive 2009/64/CE
Emission
Immunity
Motor Vehicles Directive 72/245/CE
Directive 2004/104/CE
Directive 2005/49/EC
Directive 2005/83/EC
Directive 2006/28/CE
Emission
Immunity
Motor Vehicles ECE règlement 10 rev04
Emission
Immunity
Construction machinery - Electromagnetic compatibility of machines with internal power supply NF EN 13 309
Emission
Immunity
Earth-moving machinery - Electromagnetic compatibility ISO 13 766