CE marking - EMC and radio frequency tests
Measurement at 3m in Fully Anechoic Room (FAR)
A Faraday room with ferrite tiles and pyramidal absorbers builded to be a full anechoic room can comply the site attenuation of an open area test site.
The emission measurements are equivalent and have the advantage to be also insulated from exterior sources of electromagnetic noise.
We obtain faster measurments in FAR
A FAR can be used for EMC tests (emission, immunity) and radio frequency tests.
- Radiated emission type CISPR 16-1-4, ANSI C63.4 from 30MHz to 26GHz
- Radiated immunity tests type IEC 61000-4-3, EN 61000-4-3 from 80 MHz to 6 GHz
- Radio emission type EN 300 330 / EN300220 / EN300440
Measurement at 3 or 10m in our large semi-anechoic chamber
With its dimension (15m x 10m x 7m), our Faraday room dedicated to the measurements at 3 or 10m worth its name of "large room".
With its large shielded door, these room can be used to test huge equipments.
These room can be used for EMC tests (emission, immunity) and radio frequency tests.
- Radiated emission type CISPR 16-1-4, ANSI C63.4 from 30MHz to 26GHz (possibilty to extend to 40 GHz)
- Radiated immunity tests type IEC 61000-4-3, EN 61000-4-3 from 80 MHz to 6 GHz (possibilty to extend to 40 GHz)
- Radio emission type EN 300 330 / EN300220 / EN300440
Measurement at 3 or 10m in our open area test site
Reference measurments for the emission tests, the equipment under tests is installed on a turntable (0 to 360 degrees), the height of the antenna is adjusted between 1 to 4m. For each frequency detected, the position of the turntable and the height of the antenna are optimized to obtain the high value of the RF field.
The ambiant radio frequency spectrum add an electromagnetic noise and complexify the measure and its duration.
Our open area test site is near our lab.
It is used for EMC emission tests and radio frequency tests.
- Radiated emission type CISPR 16-1-4 from 30MHz to 1GHz
- Radio emission type EN 300 330 / EN300220 / EN300440
Electrical tests, conducted emission and immunity, ...
Flickers et harmonics EN 61100 3-2 & 3-3 and EN 61100 3-11 & 3-12
- Single and three phase 16 A
- Single and three phase 32A
Conducted emission type CISPR 16-1-4/CISPR 11/CISPR 22/CISPR 14 from 9kHz to 30MHz:
- LISN 1 phase - 10A
- LISN 3 phases - 100A
- LISN 3 phases - 400A
- 1 to 6m cable slide bar for disturbing power emission
Conducted immunity:
- EN 61100 4-6 - 10Veff from150kHz to 230MHz.
Magnetic immunity:
- EN 61100 4-8 Magnetic field by immersion 30A/m 50/60Hz.
Electrical tests:
- EN 61100 4-2 Electrostatic discharge up to 30kV.
- EN 61100 4-4 CDN 3 phases 30A, amplitude burst 4.4kV.
- EN 61100 4-4 CDN 3 phases 100A, amplitude burst 4.4kV.
- EN 61100 4-5 CDN 3 phases 25A amplitude 6.6 KV.
- EN 61100 4-5 CDN 3 phases 150A amplitude 6.6 KV.
- EN 61100 4-11 1 phase, 3 phases and DC.
A recognized expertise in addition to our facilities
A know-how in technical assistance and advices to solve design issue.
Recommandations according the state of the art to take into account the EMC phenomena, including EMF.
Intervention in France and in the world on disturbed sites (EMC).
Standards - CE marking and international regulations
EMC directive 2004/108/EC
EN 55016-2-1 / EN 55016-2-2 / EN 55016-2-3
EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12
EN 61000-4-(2 à 6, 8 à 13, 16 et 17)
EN 61000-6-(1 à 4)
FCC PART 15 / ICES-003 / NMB-003 / ANSI C63.4
Medical devices directive 93/42/EEC
CEI / EN 60601-1-2
R&TTE 99/5/EC directive
EN 301 489-X and associated standards ETS
EN 300 330 / EN300220-1 et-2 / EN302291-1et-2 / EN301511 / EN300328 / EN 301908-1
Board of test method
Type | Object | Ref |
---|---|---|
Emission |
Railway applications – EMC – part 3-2 : Rolling equipment – Apparatus |
EN 50121-3-2 |
Emission Immunity |
Railway applications – EMC– part 4 : signaling and telecommunication apparatus |
EN 50121-4 |
Emission Immunity |
Fire detection, intruder and social alarm equipments |
EN 50130-4 |
Emission Immunity |
Railway applications – Electronic equipments used on rolling equipment |
EN 50155 |
Emission Immunity |
Road Traffic Signal Systems |
EN 50293 |
Emission Immunity |
Measurement relay and protection devices |
EN 50263 |
Emission Immunity |
General prescription, tests and tests conditions - Metering equipment (precision class A, B et C) |
EN 50470-1 |
Emission |
Industrial, scientific and medical apparatus |
CISPR 11 EN 55011 |
Emission | Electrical, electronical, electrical domestic and handheld tools equipments Devices with motors | CISPR 14-1 EN 55014-1 |
Immunity | Electrical, electronical, electrical domestic and handheld tools equipments Devices with motors | CISPR 14-2 EN 55014-2 |
Emission | Electrical and electronival device, information processing equipment | CISPR 22 EN 55022 |
Immunity | Information processing equipment | CISPR 24 EN 55024 |
Emission | Electromagnetic compatibility of multimedia equipment - Emission requirements | CISPR 32 EN 55032 |
Immunity | Measuring relays and protection equipment | CEI 60255-11 EN 60255-11 |
Emission | Measuring relays and protection equipment | CEI 60255-25 EN 60255-25 |
Emission Immunity |
Measuring relays and protection equipment | CEI 60255-26 EN 60255-26 |
Emission Immunity |
Medical electrical equipment | CEI 60601-1-2 EN 60601-1-2 |
Emission Immunity |
Medical electrical equipment - Part 2-4 : particular requirements for basic safety and essential performance of cardiac defibrillators | CEI 60601-2-4 EN 60601-2-4 |
Emission Immunity |
Maritime navigation and radiocommunication equipment and systems | EN 60945 |
Emission Immunity |
Low-voltage switchgear and controlgear - Part 5-1 : control circuit devices and switching elements - Electromechanical control circuit devices | CEI 60947-5-1 EN 60947-5-1 |
Emission Immunity |
Low-voltage switchgear and controlgear - Part 5-2 : control circuit devices and switching elements - Proximity switches | CEI 60947-5-2 EN 60947-5-2 |
Immunity | Electromagnetic compatibility (EMC) - Part 6-1 : generic standards - Immunity for residential, commercial and light-industrial environments | CEI 61000-6-1 EN 61000-6-1 |
Immunity | Electromagnetic compatibility (EMC) - Part 6-2 : generic standards - Immunity for industrial environments | CEI 61000-6-2 EN 61000-6-2 |
Emission | Electromagnetic compatibility (EMC) - Part 6-3 : generic standards - Emission standard for residential, commercial and light-industrial environments | CEI 61000-6-3 EN 61000-6-3 |
Emission | Electromagnetic compatibility (EMC) - Part 6-4 : generic standards - Emission standard for industrial environments | CEI 61000-6-4 EN 61000-6-4 |
Emission Immunity |
Programmable controllers - Part 2 : equipment requirements and tests | CEI 61131-2 EN 61131-2 |
Emission Immunity |
Live working - Voltage detectors - Part 3 : two-pole low-voltage type | CEI 61243-3 |
Emission Immunity |
Electrical equipment for measurement, control and laboratory use | CEI 61326-1 EN 61326-1 |
Immunity | Equipment for general lighting purposes | CEI 61547 EN 61547 |
Immunity | Installed monitors for the control and detection of gamma radiations contained in recyclable or non recyclable materials transported by vehicles | CEI 62022 EN 62022 |
Emission Immunity |
Radio receivers and transmitters | EN 301 489-01 EN 301 489 – 1 à 34 |
Emission Immunity |
Adjustable speed electrical power drive systems | CEI 61800-3 EN 61800-3 |
Emission Immunity |
Remote Control Interface Box switches 400A (ITI) | HN 64-S-44 |
Immunity | Measuring systems for gaseous fuel | OIML R140 |
Emission Immunity |
Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargers | ISO 7176-21 |
Emission Immunity |
wheeled agricultural or forestry tractors | Directive 73/322/CE Directive 2009/64/CE |
Emission Immunity |
Motor Vehicles | Directive 72/245/CE Directive 2004/104/CE Directive 2005/49/EC Directive 2005/83/EC Directive 2006/28/CE |
Emission Immunity |
Motor Vehicles | ECE règlement 10 rev04 |
Emission Immunity |
Construction machinery - Electromagnetic compatibility of machines with internal power supply | NF EN 13 309 |
Emission Immunity |
Earth-moving machinery - Electromagnetic compatibility | ISO 13 766 |